About Ahmed Abdelraheem Mahmoud Saleem

  • Viewed 356

Education

Experience

  • 2019 - 2019
    ASEC Automation at TCI Sanmar Chemicals S.A.E, Port Said,Egypt

    Electrical Engineer

    1: Responsible on PVC, VCM, Calcium and Ethylene Areas.
    2: Maintenance and Testing Low Voltage Motors and its Drive systems {Schneider MCC}.
    3: Maintenance and Testing Medium Voltage Motors 6.6 KV and it’s starters.
    4: Maintenance and Troubleshooting L.V soft starter (Schneider Altistart Telemechanic, ABB PST).
    5: Maintenance and Troubleshooting M.V and L.V AC drives {(ABB ACS 550, 580, 800, 850, 880, 1000)-Schneider Altivar 312-320).
    6: Maintenance, Testing Step-Down Transformers (Oil) (22/6.6KV-6.6/.4KV).
    7: Testing and Filtration of Oil Transformers by using Transformer Oil Dielectric Strength Tester 60KV {OTS60SK/MOT}.
    8: Troubleshooting For switchgear protection relay (Schneider SEPAM-MiCOM).
    9: Maintenance, Testing Low Voltage Circuit Breaker.
    10: Maintenance, Testing Medium Voltage Circuit Breaker (SF6) (Schneider MCset1-MCset4-Ronex).
    11: Maintenance and Testing L.V Power Factor Correction Controller Type: Schneider Varlogic VL6/VL12.
    12: Measurement the Resistance of (Transformer, Generator and CB) by using {DLR010X and Transformer Ohmmeter MT0210 Manf. Megger}.
    13: Predictive Maintenance (PD) Using Thermography technique for devices using Fluke Ti32 IR Fusion Technology.
    14: Predictive Maintenance (PD) using Partial Discharge Measurement for MV/HV Switchgears using PD SCAN Manf. Megger.
    15: Maintenance, Testing Earthing System using devices as (Chauvin Arnoux C.A6423 Earth Tester- Earth Ground Clamp Manf. Fluke1630-2FC).
    16: Maintenance, Testing Earthing System for Ethylene Transfer Pumps using device (Newson Gale Earth-Rite ER ІІ).
    17: Maintenance and troubleshooting for Battery Chargers and UPS.
    18: Maintenance and troubleshooting for Compressor units (Ingersoll – Atlas-Copco).
    19: Maintenance and troubleshooting for Generators {6.6KV Diesel Gen Manf. Kohler Dec 4000}.
    20: Protection devices used for Motors, Transformers and Generators

  • 2022 - 2019
    ASEC Automation at El Nahda Cement site, Qena,Egypt

    Electrical Engineer

    1: Responsible on Electrical Shift Activities and Troubleshoots.
    2: Maintenance and Testing Low Voltage Motors and its Drive systems {Schneider MCC}.
    3: Maintenance, Control and Protection MV 11 KV Slip Ring wound rotor Motors UP to 7.14 MW with liquid starters.
    4: Maintenance and Troubleshooting L.V soft starter (Schneider Altistart Telemechanic, ABB PST)
    5: Maintenance and Troubleshooting M.V and L.V AC drives {(ABB ACS 550, 580, 800, 850, 1000) – Siemens)
    6: Maintenance, Testing Step-Down Transformers (Oil) (11/0.4KV-11/3.3KV-11/0.72KV)
    7: Troubleshooting For switchgear protection relay (Schneider SEPAM-MiCOM).
    8: Maintenance, Testing Low voltage circuit breaker.
    9: Maintenance, Testing Medium Voltage Circuit Breaker (SF6) (Schneider MCset4)
    10: Maintenance and Troubleshooting M.V Power Factor Correction Controller.
    11: Maintenance and Troubleshooting for Cement Plant Instrumentation
    12: Technical problems Solving Control system (Classical Control – PLC ABB – PLC Siemens S7-300, S7-400, S7-1500).
    13: Maintenance and troubleshooting for Battery Chargers and UPS
    14: Maintenance and troubleshooting for Compressor units (Ingersoll – Atlas-Copco).
    15: Maintenance and troubleshooting for Generators {L.V Emergency Diesel Gen Manf. InteliLite}
    16: Protection devices used for Motors, Transformers and Generators

  • 2020 - 2021
    Egyptian Maintenance Company {EMC}{EGPC} at TCI Sanmar Petrochemicals S.A.E, Port Said, Egypt

    Electrical Engineer

    1: Responsible on PVC, VCM, Calcium and Ethylene Areas.
    2: Maintenance and Testing Low Voltage Motors and its Drive systems {Schneider MCC}.
    3: Maintenance and Testing Medium Voltage Motors 6.6 KV and it’s starters.
    4: Maintenance and Troubleshooting L.V soft starter (Schneider Altistart Telemechanic, ABB PST).
    5: Maintenance and Troubleshooting M.V and L.V AC drives {(ABB ACS 550, 580, 800, 850, 880, 1000)-Schneider Altivar 312-320).
    6: Maintenance, Testing Step-Down Transformers (Oil) (22/6.6KV-6.6/.4KV).
    7: Testing and Filtration of Oil Transformers by using Transformer Oil Dielectric Strength Tester 60KV {OTS60SK/MOT}.
    8: Troubleshooting For switchgear protection relay (Schneider SEPAM-MiCOM).
    9: Maintenance, Testing Low Voltage Circuit Breaker.
    10: Maintenance, Testing Medium Voltage Circuit Breaker (SF6) (Schneider MCset1-MCset4-Ronex).
    11: Maintenance and Testing L.V Power Factor Correction Controller Type: Schneider Varlogic VL6/VL12.
    12: Measurement the Resistance of (Transformer, Generator and CB) by using {DLR010X and Transformer Ohmmeter MT0210 Manf. Megger}.
    13: Predictive Maintenance (PD) Using Thermography technique for devices using Fluke Ti32 IR Fusion Technology.
    14: Predictive Maintenance (PD) using Partial Discharge Measurement for MV/HV Switchgears using PD SCAN Manf. Megger.
    15: Maintenance, Testing Earthing System using devices as (Chauvin Arnoux C.A6423 Earth Tester- Earth Ground Clamp Manf. Fluke1630-2FC).
    16: Maintenance, Testing Earthing System for Ethylene Transfer Pumps using device (Newson Gale Earth-Rite ER ІІ).
    17: Maintenance and troubleshooting for Battery Chargers and UPS.
    18: Maintenance and troubleshooting for Compressor units (Ingersoll – Atlas-Copco).
    19: Maintenance and troubleshooting for Generators {6.6KV Diesel Gen Manf. Kohler Dec 4000}.
    20: Protection devices used for Motors, Transformers and Generators

  • 2021 - Present
    Egyptian Maintenance Company {EMC}{EGPC} at Pharaonic Petroleum Company (PHPC) (BP JV), Port Said, Egypt.

    Electrical Engineer

    1: All Tasks and Safety Procedures are done According to British Petroleum (BP) Co Standards.
    2: Maintenance Management (PM-PD-CM-WO) Using IBM Maximo Software CMMS.
    3: Senior Authorised Electrical Personnel (SAEP) Isolating Authority (IA) Certified, Performing Authority (PA) Certified.
    4: Explosion Proof (EX) Certified As Working in Gas, Hydrocarbon Plant.
    5: Maintenance and Testing L.V Motors and its Drive systems such as {Schneider, ABB, Allen-Bradley MCC}.
    6: Maintenance and Testing Medium Voltage Motors 6.6 KV and it’s starters.
    7: Maintenance, Testing Step-Down Transformers (Dry) (6.6/.4KV).
    8: Troubleshooting For Switchgear protection relay (Schneider SEPAM-MiCOM) (ABB REF542Plus-REM615).
    9: Maintenance, Testing Low Voltage Circuit Breaker.
    10: Maintenance, Testing M.V Circuit Breaker (SF6) (Schneider MCset1-MCset4-Ronex).
    11: Testing MCB, Overload and Earth fault relay by Using Relay Test Unit Manf. Megger Sverker 780, And Protection relay Schneider TYSES using SO-Move Application.
    12: Measurement the Resistance of (Transformer, Generator and CB) by using {DLR010X and Transformer Ohmmeter MT0210 Manf. Megger}.
    13: Predictive Maintenance (PD) Using Thermography technique for devices using Fluke Ti32 IR Fusion Technology.
    14: Maintenance, Testing Earthing System using devices as (Chauvin Arnoux C.A6423 Earth Tester- Earth Ground Clamp Manf. Fluke1630-2FC).
    15: Maintenance, Testing Lightening Arrestors Protection System type: (Indelec Prevectron Version 2 and 3).
    16: Testing Batteries Characteristics Curve by using TORKEL 860 Multi Battery load unit Manf. Megger and Fluke BT521 Battery Analyser.
    17: Maintenance and troubleshooting for Battery Chargers and UPS (Convel-ABB).
    18: Maintenance and troubleshooting for Compressor units (Ingersoll – Atlas-Copco).
    19: Maintenance and troubleshooting for Generators {Diesel Gen Manf. (Caterpillar 3412, 3412STA, Kohler Dec 4000, Olympian)}, {Gas Gen Manf. (Caterpillar G3500, G3600)}.
    20: Protection devices used for Motors, Transformers and Generators.

Languages

Arabic
Proficient
English
Intermediate

Skills